Original Article

Design and Fabrication of a Conductometry System for Fast Detection of Pathogenic Bacteria in Human Urine

Mehrdad Enami 1 ORCiD, Mansour Amin 2, Pejman Shabani 1 * ORCiD, Mohammad Reza Gashtil 1

1 Department of Electrical Engineering, Mahshahr Branch, Islamic Azad University, Mahshahr, Iran
2 Infectious and Tropical Diseases Research Center, Health Research Institute, Department of Microbiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
*Corresponding Author: Pejman Shabani, Department of Electrical Engineering, Mahshahr Branch, Islamic Azad University, Mahshahr, Iran, Email: Email: p.shabani@mhriau.com

Abstract

Background: Common methods for identifying the infectious bacteria in human urine are mainly time-consuming and costly. Therefore, the most reliable method for detecting the urinary tract infections is the urine culture, which requires at least 48 hours to identify infectious factors.

Objectives: It is important to detect the bacteria in urine rapidly, simply, and accurately.

Materials and Methods: In this work, the variations in the electrical conductivity and dielectric coefficient of the urine sample due to changes in the concentration of infectious bacteria have been studied. Furthermore, an appropriate measurement system was prepared for impedancemetry and conductometry.

Results: We showed that the detection time was reduced to about an hour. Finally, the accuracy of the device for diagnosis and precision of measurement were evaluated and compared by the detection method for bacterial culture.

Conclusion: In this work, the detection time was reduced to about 1 hour.